Working Function
Count received signals
Received signals reach pre-setting value:
(1) output 5V and GND.
(2) 4 digits on display flash
Use for reject coin/banknote from coin/bill acceptor. LED sign4 digits: start from 0000 to 9999
Connection Description
1:BLACK-GND 5:BLUE- INPUT GND
2:RED-DC12V 6:BROWN- OUTPUT GND
3:BROWN-SKIP 7:BLUE-DC+5V
4:GREEN-SIGNAL INPUT
Connector Function
1 and 2: Supply Power
4 and 5:INPUT SIGNAL (For example: coin acceptor)
6 and 7: output 5V and GND when reach pre-setting
Value Setting
RESET: press ADD when standby
SET: MAX value: 0001-9999
Reach setting value, output 5V and GND
Push button SET → First digit flashes → push ADD to adjust thousands
Push button SET → second digit flashes → push ADD to adjust hundreds
Push button SET → third digit flashes → push ADD to adjust tens
Push button SET → forth digit flashes → push ADD to adjust units
the price is for 1 pcs of COUNTER only