Function Summary
lInput Voltage: DC+12V or 24V. Control voltage is based on input voltage.
Control Voltage: Input DC+12V, then control DC+12V. Input DC+24V, then control DC+24V.
l2 ways to count received signals
(1) Count on CHANNEL 1:
Push button startàSupply power to deviceàInput signal to CHANNEL 1à
Count sensor signalsàthe signals reach presettingàCut off powerà
push button startàrestart counting
Note: Push button start when countingàpauseàpush the button againàcontinue
Control MAX LOAD CURRENT: 1A
(2) Channel 1 and Channel 2: Individual counte
Receive sensor signalsàcount all
lAuto stop if no signals after start counting in pre-setting time.
Time is settable from 0 to 99 seconds.
l8 digits per channel. Count from 0.
Connection Description
lSet up Max Signal Input:
Press MODE→Digit flashes→Press MODE to change to next digit→
Press ADD to adjust on the digit you need
lSet up Auto Stop Time:
Cut off power (2) if It does not receive any signal in setting time.
Hold on MODE for 2 seconds→Digits flash→Press ADD to adjust→
Hold on MODE for 2 secondsto save
lReset:Hold on ADD for 2 seconds when standby→Reset