icon-search
icon-search
  • 7
  • 使用範例-英 EXAMPLE USE
  • 5 (2)
  • 5
  • 6 (2)
  • 3
  • 20210712_090157
  • +USB

JY-23 Pulse to RS232 Signal Converter Coin Operated for Coin Acceptor Bill Acceptor PC COM USB to PULSE

$ 16.00 USD
- +
icon-bag Add to Cart





Description

  • Input Voltage: DC+12V

  • Converter signal Pulse to RS232

  • Connect coin acceptor to PC

  • Send RS232 order to send a pulse siganl or output DC+5V

  • Usage:



Control board Introduction                                                                                                  


1: DC 12V 5.5*2.1mm

2: Pulse input 1: Channel 1

3: Pulse input 2: Channel 2

4: output 1 pulse when receive order

5/6: output/no output 5V when receiver order

7: RS232 connector

D1: light when staying power on

D2: flash when sending 1 pulse

D3: light when 5&6 outputing 5V

D4: light after receive first order.



  • Connector Define


Connection Example





RS232 Protocol

  • Specification:
    (9600,N,8,1)                      Power consumption: 50MA
    Baud rate: 9600                   Send Display: Char Format
    Parity Bit: NONE                 Receive Display: Hex Format
    Data Bit: 8
    Stop Bit: 1

  • Construction:
    Head (1) + Len (1) + Data (LEN) + XOR (1) + TAIL (1)
    Head (1): 0xF2
    Len (1): Data Length
    Data (Len): Length is based on Len (1)
    Xor (1): From Len (1) to Data (Len)
    Tail (1): 0xF3

  • Send data when receive pulse in 100MS
    Len (1): 03
    Data: Channel (1) +Pn_LL(1) +Pn_HH(1)
    Note: Low position first then high position.
    Data = CMD (1) + Result (1)
    CMD (1): Respond “order byte”, 1 byte
    Result (1): Respond order result. 0x00 indicates success.
    If value is not 0x00, it indicates fail.

  • Order Detail


No.

Action

Receive

1

5&6”: Output/ no output 5V

F2 01 30 31 F3

Success Respond: F2 02 30 00 32 F3

2

4”: output 1 pulse

F2 01 31 30 F3

Success Respond: F2 02 31 00 33 F3

3

Check total income (Channel 1+2)

F2 01 32 33 F3

Success Respond: 32(1)+count 1 (4)+count 2(4)

4

Reset inbuilt counter

F2 01 35 34 F3

Success Respond: F2 02 35 00 37 F3